Thinking its the compressor or really dont know at this point. Check that hoses are clamped tight to fitting. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. And you cant rule out a problem with the circuit board either. Find answers to your questions about all No leaks, pressure is good, suction is good, connections seem right. Water level is good, changed basket lid seal, all unions are tight. Sir, I have a Hayward Ecostar 3400 variable speed pump and will not run anymore. Hi Paul, Ants can be a problem, when they get around motors or circuit boards, but it sounds like a pump motor problem, and could simply be a weak capacitor, in the rear of the motor (black cylinder). Hi the strainer housing must need to be tightened up. Both the pump motor and Polaris are wired out of the timer and the timer seems to be working correctly and I checked it by checking the voltage at the motor with the switch in the off position and then again with the switch in the on position. Make sure pump motor is set to accept 110V (may be wired to accept 220V), and that all wires for the cord are tight, and connected correctly to terminals L1 and L2, I have a hayward super pump model c48k2n143b1 sp2607x10a and i am trying to wire on the 115v but i dont have a switch to change from 220 or 115 and no diagram on the pump i try yesterday to pump work but was not pulling the water like it is suppose to and after 3 min the pump what very hot .. so i think it is on 220v are you able to help me. Pump is grounded. Another possible cause is that the impeller is clogged with very small debris. Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? If stuck from rust build-up, move the capacitor (located at 9 oclock) and/or the thermal regulator (located at 12 oclock), out of the way, so that you can fit a 7/16 open end wrench on the slotted part of the shaft, behind the centrifugal switch that is screwed onto the end of the shaft. From the Hayward Ecostar Owners Manual: the Heat Sink Overheated error indicates that the heatsink on the bottom of the drive has overheated. Thanks. We have an Hayward SP1580X15 Power-Flo LX 1.5hp pump. Today everything was running well and than at some point the hose that takes the water to the filter came loose from the pump. Any insight? The pump was working well since opening the pool in May, but the last few days it was quite weak. I opened the control panel during a rain storm (down pour) to turn off the filter. Your chlorine generator is still producing chlorine at the moment, which is a good thing. Also check other wires in the back of the motor. You could take the motor or pump into an electrical motor shop for confirmation. Third, could be a clog in the main drain or skimmer (suction) pipes. Another piece of information is that the board was replaced back around May of this year as well as the flow sensor. Remove the back of the motor and look for anything loose wires, switches, tabs. Gas pressure is ok. Any ideas? My pump & filter are Haywards. Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. Only thing I can think of, is the Key assy aligned properly when it was screwed back onto the valve body? None of the indicating lights are on. Tested the switch on and off and it works as expected. Thanks. Went to clean the pool filter a few days later and now when turning on the pump it made a loud grinding noise. The pump never turns off but it should pull the water through constantly. The only thing I can think of now is a bad breaker box which is outside adjacent to the pump, it is 20 years old. I call that surging and its commonly caused by an air leak around the pump, either a loose pump lid, bad o-ring or loose drain plug or loose pipe coming into the pump. Hi, I have a Hayword pump and when I turn the pump on I have water coming out the bottom of the pump in the back, and trips the GFI OUTLET, could this be a bad seal? Hi John, sounds like a thermostat issue (or potentiometer for electronic heaters), although it could be another issue that just by coincidence happens when water is warm, like low flow rates. I filled the pool to the level line, but the air bubbles stayed. The pipe connection became disconnected and flooded the pool house overnight after initial opening and start up I have chalked all the connections and lubricated the basket seal. Poor connection inside the plug or socket. The motor model # is C48L2N134B1. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. Reprime the pump again, open water valves and test. Pump is 29 years old so wouldnt surprise me if impeller is failing. If you have power there, and the motor is making no sound then I would inspect closely for a loose wire on the terminal board, or a loose switch in the back, or loose capacitor wire. If theres no power at the switch/timer, go back further to the breaker. What are the amp and volt readings for the new cell? We purchased a Hayward D.E Filter last summer. Has been running great. Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. If you dont have a control system, and just a breaker box subpanel and maybe a time clock, the click could be coming from a switch inside the motor, which could be loose wires, low power, bad capacitor, loose switch, or something jamming up the motor shaft or internal fan. Sometimes it hums but wont start and other times there is nothing. Hi Bobby, so you have power at the motor, but no noise. The pump is only one year old. Not sure what to call it voltage selector perhaps? Maybe not a pump issue, but supply issue. Davy: The Super Pump comes with all these labels that say it is set up and wired for 230. Reinstall and add new DE powder. "caption": "In The Swim Blog"
"@type": "ImageObject",
I believe we have the drawing in air issue at filter, I cannot locate to purchase the o ring seal and valve cover for this model. Hi Jack, according to the manual, the Drive Error Pump is Stalled error usually refers to water or moisture on the circuit board, under the display panel. See if your test button has popped out on the outlet, or perhaps you have one on the breaker, a test/reset button. When the control box is on, go to the diagnostics menu and give me the listed T-CELL type, amps, and voltage. Remove and replace the two seal halves, in the same orientation as removed, spring half slides over impeller stem, donut half is pushed into seal plate. Other problems that could cause this could include a (very) clogged impeller, something actually preventing the shaft from turning or it could be a bad capacitor, a black cylinder in the rear of the motor. Check if the pump will now run. Troubleshooting pool heaters is a methodical process, or a process of elimination. I have a new pump and brand new grid inside my filter i have no leaks after about 10 minutes my jets stop i back wash filter and it works for about 10 min again i am stumped. Hayward Blue Essence Troubleshooting, What does your water temp say? Just disconnect wires, and replace. Blower vacuum switch open during post-purge error. regardless, i am replacing the electrical cord. Keeping the pump lid o-ring clean and well lubricated also helps, be sure to use a Teflon pool lube, and not any petroleum based (Vaseline), which makes the rubber soft and can cause cover sticking problems too. Attach a bond wire to the Eco star drive pump or tighten the loose screws on the bottom of the motor. But most likely an air leak, either before or after the pump, pool systems are supposed to be mostly air tight, though most are not completely. I opened the back and was spinning the rod and it eventually started. Maintenance. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. filter. I have a perflex ec50 that is about four years old. Ive had the pool for about a month and all has been fine but while I am ordering a new hose is there a replacement hose I can use in the meantime? Could also be a clog in the pipe. 12 ga or 14 ga? Basically it ran normal and then would get loud, and then go back to normal. Backwashing or cleaning the pump basket is the usual fix. The breaker on the panel tripped. The blower will run until error condition is corrected. I have an sp3400vsp pump. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. You can consult the flow charts for each model, to compare flow rates among two pumps, with a given (or assumed) level of resistance (feet of head). Now if you do find power at the motor, and the wires are screwed tightly, but no sound, no movement, and the breaker doesnt trip it could be a bad motor. v when it is turned to 230v and re wired for 220-230 v it makes no noise at all. Contact a professional for further assistance. Its a Hayward pump. Posted: (10 days ago) Posted: (5 days ago) Mountainside Fitness is located at 9375 E Bell Rd, Scottsdale, AZ 85260.Mountainside Fitness can be contacted at (480) 502-2096. 6. 2. loose pipe coming into pump, drawing air around fitting threads Occasionally, while running, it trips the breaker. Now there is no water running from the pool to the motor basket. easier. Do I need to do something else to get it to prime faster? near the end of last season it started loosing its prime on and off. I turned it on and it ran fine for about one hour. I have a Hayward 1.65 variable speed pump it is on a timer for high and low. I have an Ecostar That has developed a pinhole spray leak at the top of where the pump housing oring sits between the pump and motor. I checked the voltage at the back of the motor and have 240 volts. I even removed the outflow from the filter and ran that directly in case the filter was clogged. Go to the grocery store and come back and its dead. The pump stopped priming and allowed water to just flow through but not pressurize the closed filter basket part that is right before the pumpso it looks like a waterfall in the basket flowing from the pipe coming from the pool to the lower end going into the filter. "publisher": {
Hmmm, now if the breaker were stopping the power from flowing to the switch, the timeclock would lose time, and would not turn itself on. If it is cycling on/off (motor turning on/off) more rapidly, that would usually indicate loose wires, loose breaker, broken wires (sometimes inside the flexible conduit). Hi we have a Hayward DE filter for a 2040 in ground. If you have power coming into the motor, but no pump noise, check (Power off) that wire connections are tight, and inspect the wire for breaks or damage. After communication is established, if it is lost for 30 s, the error will be displayed. My pump, when in the normal running position, leaks water in a slow steady flow out the tubing used for backwashing. I replaced the capacitor last year. Blower will operate until error condition is corrected. Hi, yes shaft seal failure. Automatic restart is 2 minutes after the error condition is corrected and the limit string closes. When I turn the switch on for the pool, the breaker flips immediately. Your 1 hp Hayward Superpump can pump 75 gallons per minute, which is too much flow for most AG pool filters.
Razor Edge Arrowhead Guide, Judge Sarah Jones Will County Il, Articles H